![]() If you are using the same model version, but producing different outputs by using different input parameters, calibration or setup, we need to be able to distinguish such outputs see notes for ISIMIP3 and water regional data below.You can use a simple version numbering: MODEL-v1, following a semantic versioning: MODEL-200 (for version 2.0.0), or use the year of application of the model: e.g., MODEL-2020.If you develop further versions of your own model, the names of these versions should be distinguishable.For example, you could name it -, but if you are using different input data, you could name it.If you are running a different version of an existing model, we recommend you agree a naming convention with the authors of the first version.Versioning of the model output does not only apply to changes in the computational logic of the model, but also to input parameters, calibration or setup – See special cases below.You can download a ISIMIP2b example NetCDF file to help you with your file preparation.Before submitting complete simulations, please upload few sample files for checking (so we can assess whether your files will pass our quality checks or not) and send a quick email to to let us know - This could save much time and bandwidth!.Incorrect formatting can delay the analysis of your files. Please comply precisely with the formatting specified below to facilitate comparison among different models and between global and regional scale.Before uploading your files, please review the Simulation Protocols corresponding to your simulation round.On request we offer consistency checks for your model. All data uploaded will be quality checked by the ISIMIP data managers, with the purpose of having all runs available with a consistent set of variables.The '_code' and '_doc' folders are destined to storing code, scripts and documentation. do not create additional subfolders and only store NetCDF files.after file transfer give group write permissions to all files, e.g with 'chgrp -R bb0820 MODEL_FOLDER'. ![]() If you don't find the folder structure for your model, please get in contact with the data management and we will create the directories as soon as possible.Be sure to place your files in the correct folders, incorrect upload can delay the processing of your files. There you will find subfolders corresponding to the climate forcing and the time periods of the simulation round. You will submit your simulations to the Upload folder at DKRZ below /work/bb0820/ISIMIP//UploadArea/// _tmp/.To access this server, you will need an account, please see Accessing ISIMIP data on the DKRZ server for more information. Simulations are submitted to a dedicated file system on a central server located at DKRZ Hamburg.
0 Comments
Leave a Reply. |